AMTA Paper Archive


Welcome to the AMTA paper archive. Select a category, publication date or search by author.

(Note: Papers will always be listed by categories.  To see ALL of the papers meeting your search criteria select the "AMTA Paper Archive" category after performing your search.)


Search AMTA Paper Archive
    
    




Sort By:  Date Added   Publication Date   Title   Author

AMTA Paper Archive

Hand Held Imaging Verification Radar for LO Platforms Using Radar/Target Location Registration
A. Moghaddar,L. Sheffield, R.C. Reynolds, R.J. Jost, November 2005

A portable, handheld imaging verification radar (HIVeR) system is designed to verify the RCS integrity of a low observable (LO) platform. The HIVeR is the latest generation to a previously designed and field-tested system (SARBAR) that produced radar images of targets in real-time. For applications with LO aircraft, an objective of the present technology is to extend the first-generation SARBAR system performance to easier use, higher sensitivity, and effective pass/fail decisions for selected regions on the aircraft outer mold line (OML). A novelty of the HIVeR design is an automatic registration scheme incorporated into the radar set. The location and orientation of the HIVeR unit is continually recorded using a precision position and orientation monitoring system. This registration process locates the handheld radar antenna position and orientation with respect to a fixed coordinate system. Similarly, the region-of-interest (ROI) on the aircraft surface is registered in this fixed coordinate system. An important feature of the new HIVeR is its capability to form calibrated radar images along a surface defined by the OML of the LO aircraft. This enables the radar to produce images that can be related to the RCS integrity of the ROI. The image along the OML can be used for pass/fail decision-making by comparing the image with a “gold standard” image for the same region.

A High Performance Combined NF-FF Antenna Test Facility
U. Shemer,C.T. Tong, November 2005

DSO National Laboratories (DSO) has commissioned a state-of-the-art combined near-field and far-field antenna test facility in 2004. This facility supports highly accurate measurement of a wide range of antenna types over 1–18 GHz. The overall system accuracy allows for future extensions to 40GHz and higher. The 11.0m x 5.5m x 4.0m (L x W x H) shielded facility houses the anechoic chamber and the control room. As the proffered location for this indoor facility is on top of an existing complex instead of the ground floor, antenna pick­up is facilitated by a specialized loading platform accompanied by a heavy-duty state of the art fully automated 2.0m x 3.0m (W x H) sliding door, as well as an overhead crane that spans the entire chamber width. Absorber layout comprises 8-inch, 12-inch, 18-inch and 24-inch pyramidal absorbers. The positioning system is a heavy-duty high precision 3.6m x 2.9m (W x H) T-type planar scanner and AUT positioner. The AUT positioner system is configured as roll over upper slide over azimuth over lower slide system. This positioning system configuration allows for planar, cylindrical and spherical near-field measurements. A rapidly rotating roll positioner is mounted on a specialized alignment fixture behind the scanner to facilitate far-field measurements. Instrumentation is based on an Agilent PNA E8362B. Software is based on the MiDAS 4.0 package. A Real-Time Controller (RTC), accompanied by an 8-port RF switch, facilitates multi-port antenna measurements, with the possibility of interfacing to an active antenna.

A Simple Probe Calibration Method of a New Compact Spherical Near-Field Measurement System for Antennas from 1 GHz to 10 GHz
M. Hirose,K. Komiyama, S. Kurokawa, November 2005

ABSTRACT We have developed a new compact spherical near-field measurement system using a photonic sensor as a probe and successfully measured the 3D antenna patterns of a double-ridged horn antenna from 1 GHz to 10 GHz. This system consists of a compact spherical scanner and a photonic sensor that is used for the probe of the spherical near-field measurements. In our system, only one probe can be used for the wide frequency range measurements and the probe compensation is not needed in the measurements. For the system, we propose a simple calibration method using a double-ridged horn antenna for our system. We calibrate the system by measuring the double-ridged horn antenna on the reasonable assumption that the antenna efficiency is 100 %. Comparing the absolute gain obtained by the proposed calibration method with the one decided by using three-antenna method at far-field range, we show that the agreement is good within 1 dB over the whole frequency range.

Planar Near-field Measurement Results at 94 GHz Using Probe Position Correction
J. Guerrieri,D. Tamura, K. MacReynolds, M. Francis, R. Wittmann, November 2005

This paper presents results of planar near-field measurements at 16, 35 and 94 GHz using probe position correction algorithms. The algorithms correct for position errors of the probe near the scan plane. The probe’s actual position is measured using a laser tracker integrated into the planar-near-field scanning system at NIST. The laser tracker simultaneously obtains probe-position information at each point where amplitude and phase data are acquired during planar near-field antenna measurements.

An Apparent Discrepancy Between Impedance Mismatch Factors for Near-Field and Far-Field Measurements
D. Hess, November 2005

In making accurate measurements of antenna gain one must correct for the impedance mismatches between (1) the signal generator and transmitting antenna, (2) between the receiving power sensor and the receiving antenna and (3) between the signal generator and receiving power sensor. This is true for both far-field gain measurements and near-field gain measurements. It has recently come to our attention that there is a lack of clarity as to the form the mismatch factor should take when correcting near-field measured data. We show that a different form of impedance mismatch factor is to be used with the voltage domain equations of near-field than has been used with the power domain Friis transmission equation.

Low Cost and High Accuracy Alignment Methods for Cylindrical and Spherical Near-Field Measurement Systems
J. Demas, November 2005

Precise mechanical alignment of motion axes of both cylindrical and spherical near-field systems is critical to producing accurate data. Until recently the only way to align these types of systems was to employ traditional optical tooling (i.e. jig transits, theodolites). Alignment by these methods is difficult, time consuming, and requires specialized training. More recently, laser trackers have been used for this type of alignment. Unfortunately, these devices are expensive and demand an even higher level of operator training. This paper describes the use of low cost alignment tools and techniques that have been developed by Nearfield Systems, Inc. (NSI) that greatly simplify the alignment process. Setup and alignment can be performed in a very short period of time by technicians that have been given minimal training. Suitable optical alignment procedures when followed by the use of electrical alignment techniques [7] yield sufficient alignment accuracy to permit testing up to Ku-band.

Angular Errors In Polarimetric Radar Cross Section Calibration Using A Rotating Dihedral
L Muth,C. William, D. Morales, T. Conn, November 2005

We examine how accurately the transmit and receive parameters of a radar cross section measurement sys­tem can be determined by use of a rotating dihedral as the polarimetric calibration device. We derive expres­sions for the errors due to misalignment in the angle of rotation. We obtain expressions for the angles a0,hv and a0,vh for which the measured cross-polarization ratios of a target vanish. Since the theoretical cross-polarization of a cylinder is 0, we can .nd the calibra­tion bias-correction angles. We use simulated and real data to demonstrate the robustness of this bias-angle correction technique. We derive expressions for the uncertainty in the polarimetric system parameters.

The Long String as a Field Probe
E. Knott,P.S. Wei, November 2005

wall or ceiling. The resulting motion changes the angle of the The incident field in the test zone can be measured using one-way string with respect to the incident field direction, during which probe antennas or passive two-way reflectors. In most cases time the coherent radar echo is recorded as a function of the string neither the probe antenna nor the passive reflector is very large, angle. The coherent signal-vs-angle data are then transformed to usually only a few wavelengths at best. It must be rolled across the cross-range domain using the fast Fourier transform (FFT), the range on carriages or raised up and down on towers, and the whence we obtain a chart of the incident field amplitude as a distance moved must somehow be measured. If a passive function of cross-range distance. Numerical examples are reflector is used as a probe, the carriage system must be shielded presented that show how variations in the incident field influence with absorbers and the reflector must be mounted on low-the string echo. A sample of experimental data shows that the reflectivity support structures. In addition to the hazard of processed data are readily interpreted. contaminating reflections, the mere assembling of all this equipment can be a significant task.

Spherical Near-Field Arch Range Upgrade
j. Aubin,A. Kipple, C. Arnold, J. Puri, November 2005

An upgrade to the large 75 foot radius spherical arch range at the U.S. Army Electronic Proving Ground at Ft. Huachuca, AZ has presented a complex design challenge in order to accommodate multiple test requirements, including both far-field and near-field measurements, as well as antenna under test (AUT) mode switching, over a wide frequency range. The range features a 60 foot diameter turntable (capable of supporting 80 tons) for azimuth positioning of large vehicles. The large arch/turntable positioning system combination presents a number of design issues in the implementation of a high performance, wideband RF subsystem. In addition, a significant requirement for this range is to allow either the probe mounted on the arch or the AUT mounted on the vehicle to transmit. The RF subsystem design utilizes the Agilent PNA in conjunction with the Agilent 85310 Distributed Downconverter system. Location of all the primary RF components are key issues in achieving sufficient transmit power, LO power, and receive sensitivity. Moreover, the selection and placement of the long RF cable runs has a significant impact on system level performance, and required thorough investigation. A unique utilization of available synthesizers provides a compact physical configuration and also provides an increase in speed over other multiple source configurations. This paper examines the design considerations for the RF subsystem and the configuration for achieving both near-field and far-field measurements for the case of the AUT transmitting as well as receiving.

Improving Positioning System Performance using Advanced Control Algorithms
R. Braun,M. Pinkasy, S. Dreizin, November 2005

This article will focus on some of the Modern high-performance antenna measurement technologies and techniques incorporated inranges demand enhanced performance from the ORBIT/FR’s new positioner controllers in orderpositioning systems, for both static and dynamic to achieve the positioning accuracies andaspects of the required test scenario. Accurate performance required in current antenna static and dynamic positioning, as well as measurement systems.

European Measurement Expertise Mapping within the European Antenna Centre of Excellence
L. Boccia,G. Amendola, G. Di Massa, O. Breinbjerg, November 2005

In this paper is presented the first European mapping of the antenna measurement expertise. This initiative is conducted in the framework of the Antenna Centre of Excellence (ACE) of the European Community. This mapping has been set-up with the intent to provide all the European scientific and industrial community with a valid means to improve and facilitate the research and development activities in the field of antennas. The collected information will serve to create a valid and new service for all potential users of antenna measurements, in particular from the wireless communication industry, by witch it will be identify and contact antenna measurement facilities. The first results indicated a significant and encouraging reaction to this initiative with more then 50 European facilities registered into the database. The next step is the integration of non European institutions.

Facility Comparison and Evaluation Using Dual-Ridge Horn
L. Foged,J. Zackrisson, M. Castaner, O. Breinbjerg, P. Garreau, S. Pivnenko, November 2005

In the frame of Activity 1.2 "Antenna Measurement Techniques and Facility Sharing" of the EU network "Antenna Center of Excellence. (ACE) an activity on comparative measurements has been performed. The ongoing activity involves different test facilities and a 0.8-12GHz dual ridge horn. The facility comparison activities will be extended to more facilities within and outside Europe in the following two years. The participating facilities in this campaign where: SATIMO, the technical university of Denmark (DTU), The technical university of Madrid, Spain (UPM) and Saab Ericsson Space, Sweden (SES).

Measurement of the Propagation Constant of Surface Waves on a Periodic Array
D. Janning, November 2005

A technique is proposed to measure the propagation constant of surface waves on a periodic dipole array using a waveguide simulator. Due to the slow wave characteristic of surface waves, it is necessary to present an evanescent waveguide mode to the plane containing the elements. Two techniques for sensing the element currents are outlined.

Effects of Array Panel Joint Discontinuities on RF Calibration
V. Tripp,D. Wright, G. Wilson, R. Hemphill, R. Parks, November 2005

In this paper is presented an experimental investigation of conventional array calibration in the presence of various kinds of joint discontinuities between array panels. Two rigid array panels were positioned such that the element lattice was continuous across a narrow joint. Three kinds of discontinuities were applied to the joint: (1) an angle, (2) a gap (including an edge), and (3) a step between panels. Each type was investigated for joints oriented in the E-plane and the H-plane. Each discontinuity was also varied in magnitude so as to observe parametric effects. Planar near-field-range (NFR) measurements were made in a conventional array calibration mode and a near-field pattern mode. Processing included separating the pattern component due to element transmission (impedance) change from that due to pattern shape change. Results show that conventional calibration methods quickly become inadequate to calibrate these discontinuities because they change element pattern shapes.

Method for Selecting Sources to Calibrate a Non-Rigid Phased Array
G. Brown,D. Wright, G. Wilson, R. Parks, November 2005

Abstract— A method is proposed that will optimally se­lect the placement of sources to aid in the calibration of a phased array of scalable panels that is mounted on a station­ary, ground-based, non-rigid frame. A cost function based on the Cramer-Rao Lower Bound is optimized through con­strained minimization. The array is constructed from ide­alized (non-deforming) subarray panels that have unknown perturbations in orientation and location. To demonstrate the proposed method, several case studies are investigated involving combinations of known calibration sources.

Influence of Truncation of Near-Field Data in Calibration of Phased Array Antennas
A. Boomstra, November 2005

In this paper, reduction of the near-field scanplane in calibration of phased array antennas is discussed. In general, truncation of near-field data can give a considerable reduction of acquisition time. This particularly applies in a larger extent to phased array measurements, where a high number of channels is measured in the calibration process. Also, relative small equipment can be used to measure relative large antennas, which can be cost-effective. In this paper, it is shown that under certain conditions the scanplane, and therefore acquisition time, can be reduced substantially. Based on an example, different scanplane sizes and reduction techniques are considered to investigate and estimate the influence of truncation size on the error in the calibration parameters.

A Linear Measurement System for Large Array Antennas
J.L. Besada,C. Martinez, F. Martin, M. Calvo, M. Sierra-Castaner, November 2005

A system for measuring large linear arrays of antennas has been developed, fabricated and tested. The system consists on a 12 meters structure where the antenna under test (a L band array of dipoles in this case) is positioned. The measurement probe (another dipole) moves on a linear slide and stops in front of each element of the array to acquire the electric field. All the system is installed on an semi-anechoic chamber, that can be lifted (with two synchronized stepped motors). This semi-anechoic chamber covers the top and side parts of the structure. The bottom part consists on a metallic reflector, that controls the reflections from each antenna element. Once the data is acquired, the data are processed to obtain the far field patterns and parameters of the antenna array (element amplitude and phase, beam width, side level, beam pointing …) All the results are presented in a windows environment, and all the system is integrated in a friendly user interface.

An Improved Version of the Circular Near-Field to Far-Field Transformation (CNFFFT)
I. LaHaie,C. Coleman, S. Rice, November 2005

For many years now, GDAIS has described the devel­opment, characterization, and performance of an image-based circular near field-to-far field transformation (CNFFFT) for predicting far-field radar cross-section (RCS) from near-field measurements collected on a cir­cular path around the target. In this paper, we present an improved version of the algorithm that avoids a sta­tionary phase approximation inherent in earlier ver­sions of the technique. The improvement is realized by modifying the range-domain weighting used to imple­ment the frequency derivative in the existing method. A similar modification was presented in the context of lin­ear near-field measurements in an earlier AMTA paper. Numerical simulations are presented that demonstrate the improvement afforded by the technique in predict­ing far-field RCS patterns from near-field data collected using typical bandwidths and standoff distances. An additional benefit of the revised algorithm is that it readily admits a formulation that includes antenna pat­tern compensation, as described in a companion paper.

Antenna Pattern Correction for the Circular Near Field-to-Far Field Transformation (CNFFFT)
I. LaHaie,C. Coleman, S. Rice, November 2005

In previous work [1], we presented an antenna pattern compensation technique for linearly-scanned near field measurements. In this paper, we present a similar tech­nique to mitigate the errors from uncompensated azi­muthal antenna pattern effects in circular near-field monostatic radar measurements. The antenna pattern co mpensation is implemented as part of an improved algorithm for transforming the near-field measurements to the far-field RCS. A description of this improved circular near field-to-far field transformation CNFFFT technique for isotropic antennas is presented in a com­panion paper [2]. In this paper, we formulate the near-field signal model in the presence of an azimuthal an­tenna pattern under the same scattering approximation used in the isotropic CNFFFT. Using this model, we derive a modified version of the CNFFFT that includes antenna pattern compensation. Numerical simulations are presented that demonstrate the ability of the tech­nique to remove antenna pattern errors and improve the accuracy of the far field RCS patterns and sector statistics.

Statistical Analysis of Direction Finding Ambiguity as a Function of Receiver Noise
B. Fischer,S. Schneider, W. Baker, November 2005

The linear phase interferometer (LPI) has long been a popular means for performing direction finding (DF). Most texts treat the error terms associated with LPI-DF determination with approximation, such that the error formulae given are a generalized bound, useful for sys­tem engineering and design. For certain applications, however, it is important to understand the error associ­ated with LPI-DF in more detail. Related work has ac­complished this via Monte Carlo simulations for specific comparisons [5, 6]. To provide an improved (and more general) understanding, we have formulated a rigorous receiver noise error distribution that enables direct de­termination of bias and variance in LPI-DF. The ap­proach can be generalized to an arbitrary number of simultaneous antenna element apertures.







help@amta.org
2024 Antenna Measurement Techniques Association. All Rights Reserved.
AMTA_logo_115x115.png
 
 

CONNECT WITH US


Calendar

S M T W T F S
1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30
31