AMTA Paper Archive


Welcome to the AMTA paper archive. Select a category, publication date or search by author.

(Note: Papers will always be listed by categories.  To see ALL of the papers meeting your search criteria select the "AMTA Paper Archive" category after performing your search.)


Search AMTA Paper Archive
    
    




Sort By:  Date Added   Publication Date   Title   Author

Calibration

Development of a MATLAB Toolbox to Assist in the Process of RCS Range Calibration
R.J. Jost (Utah State University),B.M. Welsh (Mission Research Corporation), November 2003

Over the past few years, range certification activities have become more commonplace, as industry, government and academia have embraced the process and acted to implement documented procedures at their facilities. There is now a significant amount of documentation laying out the process, as well as templates to assist ranges in developing their range books. To date, however, there have been fewer examples of useful tools to assist the ranges in better understanding how the process will affect their specific range. The authors have developed a first generation MATLAB toolbox designed to provide ranges a “what-if” capability to see the impact of specific range errors on the range’s operations. Included within the toolbox are several types of additive and multiplicative errors, as well as means of modeling various aspects of radar operation.

An Approach to the Evaluation of Uncertainties for Complex RCS Measurement Data
J. Pinto (BAE SYSTEMS Advanced Technology Centre),K.L. Ford (BAE SYSTEMS Advanced Technology Centre), L.D. Hill (BAE SYSTEMS Advanced Technology Centre), November 2003

The Radar Cross Section (RCS) measurement facility operated by the Stealth Materials Department of BAE SYSTEMS Advanced Technology Centre in the UK is an invaluable tool for the development of low observable (LO) materials and designs. Specifically, it permits the effect of signature control measures, when applied to a design, to be demonstrated empirically in terms of the impact on the RCS. The facility is operated within a 3m by 3m by 12m anechoic chamber where pseudo-monostatic, co-polar, stepped frequency data for a target can be collected in a single measurement run over a frequency range of 2- 18GHz, and for a range of azimuth and elevation angles using a Vector Network Analyser (VNA). The data recorded consists of the complex voltage reflection coefficients (VRC) for the chosen range of aspect angles. This includes data for the target, mount, calibration object, and the associated calibration object mounting where significant. All data processing is conducted offline using a bespoke post processing software routine which implements software time domain gating of the raw data transformed into the time domain prior to calibration. The significant sources of type A (random) and B (systematic) uncertainties for the range are identified, grouped, and an approach to the determination of an uncertainty budget for the complex S21 data is presented. The method is based upon the UKAS M3003 guidelines for the treatment of uncertainties that may be expressed by the use of real, rather than complex numbers. However, a method of assessment of the uncertainties in both real and imaginary parts of the complex data is presented. Finally, the uncertainties estimated for the raw VRC data collected are propagated through the calibration and the uncertainty associated with the complex RCS of a simple target is presented.

ARKEN, A Measurement System for Dynamic Full-Scale RCS Measurements and ECM Evaluations in Operational Environments
S. Gadd (Swedish defence research agency FOI),J. Gustavsson (Swedish defence research agency FOI), M. Wilow (Swedish defence research agency FOI), N. Karlsson (Swedish defence research agency FOI), N-U Jonsson (Swedish defence research agency FOI), November 2003

To determine the radar cross section of full-scale objects in their operational environment, and for doing countermeasure evaluations, a radar measurement system has been developed. The system is mobile and flexible and can hence be placed in different surroundings. Its main objective is to make trustworthy and accurate measurements of the RCS of ground-, seaand air targets. This is achieved by a calibration procedure that is performed in connection to all measurements. The measurement system is well suited for RCS measurements in dynamic scenarios. The system can transmit radar signals that resemble the signals of existing threat systems. This property together with the fact that the system at the same time measures both the RCS of the target and the effects of ECM make the system well suited for ECM evaluation. Measurements have been made of many different types of targets on land, at sea and in the air. Different types of ECM, e.g. chaff, has also been evaluated.

Built-In Performance Monitoring Systems for Phased-Array Antennas with Binary Phase Shifters
V.I. Markov (UKRSPETSTECHNIKA),A.F. Kozlov (UKRSPETSTECHNIKA), November 2003

An advanced method of phased-array antennas (PAA) performance monitoring is presented in this paper. It allows receiving more accurate results for PAA with binary phase shifters. The special attention is paid to such practical aspects of design and application of built-in performance monitoring systems, as the algorithm of controlled channel signal isolation, choice of the location of probe antennas and transfer matrix calibration which is necessary for PAA performance monitoring at system level.

Uncertainty Analysis on the RCS Measurements From a Pair of Ultraspheres
A.W. Reed (The Boeing Company),C.N. Ericksen (The Boeing Company), D.P. Morgan (The Boeing Company), P.S.P. Wei (The Boeing Company), November 2002

In 2001, the Boeing 9-77 Indoor Compact Range successfully passed the range certification process. In preparation and during the On-Site Review in October 2001, RCS data on a pair of ultraspheres for the dualcalibration were collected. In this paper, we analyzed the data with regard to uncertainty analysis. An empirical approach for compensating the systematic error is presented.

WINDSAT Antenna Testing
W.L. Lippincott (Naval Research Laboratory),T. Gutwein (Microstar Corporation), November 2002

WINDSAT is a satellite system designed to be a demonstration of passive microwave polarimetry to measure ocean surface wind speed and direction. The polarimeter works off the crosspol components of the antenna, necessitating high performance requirements both in the building and testing of the antenna. The calibration of the reflector antenna system will be discussed in this paper, along with various analysis done for the project and verified by range measurement.

Correcting Dual Port Probe's Port-to-Port Calibration Using Near-Field Measurements
A.C. Newell (Newell Near-Field Consultants),J. Way (TRW Space and Electronics Group), November 2002

When a dual port probe is used for near-field measurements, the amplitude and phase difference between the two ports must be measured and applied to the probe correction files so that the measurements and calculations will have the same reference. For dual port linear probes, the measurement of this “Port-to-Port” ratio is usually accomplished during the gain or pattern measurements by using a rotating linear source antenna.1 When a dual port linear probe is used to measure a circularly polarized antenna, the uncertainty in this Port-to-Port ratio can have a significant effect on the determination of the cross polarized pattern. Uncertainties of tenths of a dB in amplitude or 1-3 degrees phase can cause changes in the cross polarized pattern of 5-10 dB.2 3 The paper will present a method for measuring the Port-to-Port ratio on the near-field range using a circularly polarized antenna as the AUT (Antenna Under Test). The AUT does not need to be perfectly polarized nor do we need to know its correct polarization. The measurements consist of two separate near-field scans. In the first measurement the probe is in its normal position and in the second it is rotated about the Z-axis by 90 degrees. A script then calculates the Port-to-Port ratio by comparing the crosspolarization results from the two measurements. Uncertainties in the Port-to-Port ratio can be reduced to hundredths of a dB in amplitude and tenths of a degree in phase. Measurements were taken at TRW’s Large Horizontal Near-field Antenna Test Range.

VHF Capability and RCS Measurements from Long Cylinders
P.S.P. Wei (The Boeing Company),A.W. Reed (The Boeing Company), C.N. Ericksen (The Boeing Company), November 2002

In order to better understand the capability and limitation of the radar in the VHF band, we present the results from RCS measurements on simple calibration objects of sizes from small to large. Though the uncertainty for measuring a small object is usually well behaved to within +0.2 dB, the greatest difficulty for a large object is the lack of knowledge on the distribution of the incident field. Some qualitative ideas may be obtained from fieldprobes along a few directions. Yet, a thorough investigation of the field in 3-D as a function of the frequency and polarization is generally beyond time and budget constraints. For the special cases of long and thin cylinders at broadside, we find that the difference in HH-VV is very sensitive to ka, which allows us to distinguish them apart.

Design and Analysis of a New Angularly Insensitive RCS Calibration Device
B. Kent (Air Force Research Laboratory),Kueichien C. Hill (Air Force Research Laboratory), B. Fischer (Veridian Systems Division), E. LeBaron (Veridian Systems Division), G. Fliss (Veridian Systems Division), I. LaHaie (Veridian Systems Division), P. DeGroot (Boeing Phantom Works), November 2002

The accurate measurement of static Radar Cross Section (RCS) requires precise calibration. Conventional RCS calibration objects like plates and cylinders are subject to errors associated with their angular alignment. Although cylinders work well under controlled alignment conditions, and have very low targetsupport interaction, these devices may not always suitable for routine outdoor ground-plane RCS measurements. We seek a design which captures the low interaction mechanisms of a cylinder, yet can be easily aligned in the field due to its excellent angular insensitivity. In a sense, this target has the best characteristics of both the cylinder and the sphere. This paper will describe the design of a "hypergeoid", a new calibration device based on a unique body of revolution. Calculations and measurements of some elementary hypergeoids are presented.

Outdoor Low Frequency Bistatic Far Field Radar Cross Section Measurements
B. Schardt (NAVAIR Weapons Division),P. Liesman (NAVAIR Weapons Division), R. Young (NAVAIR Weapons Division), November 2002

The bistatic radar signature of military systems is of interest for various applications including performance evaluation of semi-active missile systems, surveillance systems, and survivability assessment. While bistatic radar cross section (RCS) measurements have been made for high frequencies at several U.S facilities, there has been little reported work in low frequency bistatic RCS measurements. This paper presents the results of recent low frequency coherent bistatic RCS measurements from 210 MHz to 1.99 GHz at bistatic receiver angles of 0°, 35°, 70°, 120° and 145°. These measurements were successfully completed at the Naval Air Systems Command Weapons Division Etcheron Valley Range (EVR), formerly known as Junction Ranch (JR), China Lake, California This paper describes the process and provides results of low frequency bistatic RCS measurements on a hemisphere-capped cylinder target. Comparisons are presented of measured data to predicted results from moment method models of the calibration object and the cylinder target. Methodologies used in optimizing RCS data quality are also provided.

Development, Measurement, and Analysis of a Wideband Optically Multiplexed Beamformer Architecture (WOMBAT)
P. Couper (Technology Service Corporation),K. Thomson (Naval Surface Warfare Center), R. Davis (Naval Surface Warfare Center), T. Closser (Naval Surface Warfare Center), November 2002

A Wideband Optically Multiplexed Beamformer Architecture (WOMBAt) was developed and characterized at the Crane Naval Surface Warfare Center Active Array Measurement Test Bed (AAMTB) facility. The project included development and integration of the WOMBAt photonic beamformer with the Active Array Measurement Test Vehicle (AAMTV). The AAMTV is a 64-channel transmit-receive (TR) module based phased array beamformer that is integrated with the AAMTB facility 12’x9’ planar near-field scanner. The AAMTV provided phase trimming and a small amount of electrical delay while the WOMBAt provided longer optical delays using commercial-off-the-shelf (COTS) components typically manufactured for the telecommunication industry. By integrating the WOMBAt with the AAMTV, a highly flexible test environment was achieved that included system calibration, multi-frequency scanning, and antenna pattern analysis. This paper presents antenna pattern results showing less than 0.7 dB of amplitude variation over the frequency range from 9 to 10 GHz at each of the measured nominal steering angles. The beamformer was steered to greater than ±69 degrees with an observed beam squint from 9 to 10 GHz of less than 1 degree.

Phase Calibration of a 2 by 2 Phased Array GPS Antenna Using Real and Simulated GPS Signals
L.L. Liou (Air Force Research Laboratory),C.R. Burneka (Air Force Research Laboratory), D.L. Lin (Air Force Research Laboratory), J. Shaw (Air Force Research Laboratory), J. Valentine (Air Force Research Laboratory), J.B. Tsui (Air Force Research Laboratory), S.L. Osman (Air Force Research Laboratory), November 2002

Software GPS receiver development has been undertaken. We are particularly interested in improving the GPS signal-to-noise/interference ratio using a beam forming techniques. The phase relationship among the antenna array elements requires careful calibration. In this study, we will report a phase calibration technique for a 2 by 2 GPS antenna array using both simulated and real GPS signals. This technique is based on the GPS signalprocessing algorithm developed for the software GPS receiver. A four-channel digital data collecting system was used in the experiment. For a simulated GPS signal, the experiment was conducted in an anechoic chamber in which a GPS simulation system was facilitated. For real GPS signals, we conducted the experiment on a rooftop to receive the signal from GPS satellites. The calibration verified the coherent nature of the signals among the elements. The results also allowed the source's direction to be determined.

AFRL Advanced Compact Range RCS Uncertainty Analysis for a General Target
B. Welsh (Mission Research Corporation),B. Kent (Air Force Research Laboratory/SNS), B. Muller (Mission Research Corporation), November 2002

A calibration uncertainty analysis was conducted for the Air Force Research Laboratory’s (AFRL) Advanced Compact Range (ACR) in 2000 [1]. This analysis was a key component of the Radar Cross Section (RCS) ISO-25 (ANSI-Z- 540) Range Certification Demonstration Project. The scope of the RCS uncertainty analysis for the demonstration project was limited to calibration targets. Since that time we have initiated a detailed RCS uncertainty analysis for a more typical target measured in the ACR. A “more typical” target is one that is much larger with respect to wavelength than the calibration targets and characterized by a wide dynamic range of RCS scattering levels. We choose a 10’ ogive as the target due to the fact it is a large target, exhibits a wide dynamic range of scattering, and the scattering levels can be predicted using readily available CEM codes. We will present the methodology for the uncertainty analysis and detailed analyses of selected component uncertainties. The aspects of the uncertainty analysis that are unique to the “typical target” (i.e., a non calibration target) will be emphasized.

Near Field Calibration for Large Reflectors
W.L. Lippincott (Naval Research Laboratory),M. Smythers (Microstar Corporation), T. Gutwein (Microstar Corporation), Peter J. Souza (Blaise Engineering), November 2002

This paper presents a 'mid-range' calibration technique, now being developed for a 60 ft. diameter reflector site. With this technique, near-field amplitude and phase is collected at a calibration tower as the reflector scans across it. The mid-range 'near-field' data is then transformed to a far-field pattern using a Fourier transform technique. Information on far-field EIRP, directivity, pointing, axial ratio and tilt, as well as encoder timing is obtained with accuracies comparable to standard measurement techniques. A particular advantage is that the system, once set-up, can be used on a regular basis without impacting site operations.

Improved Procedure for NFR Error at Off-Probe-Calibration Frequencies
R. Wilson (Space Systems/Loral),W. Scott (Space Systems/Loral), November 2002

Calibrated probe complex pattern data is used in planar NFR (near field range) data processing to remove the effects of the probe on the measurement. In a prior paper [1] we proposed a procedure to estimate the measurement error (uncertainty) introduced into a near field antenna radiation pattern measurement due to test frequencies that do not coincide with available calibration frequencies of the range probe. Our prior paper resulted in a “19th term” which was added to the well known NIST NFR 18 Term Error Table used to evaluate the unavoidable uncertainty of far-field radiation patterns derived from a near field scan of a given AUT (antenna under test). A limitation of this procedure, pointed out in our prior paper, is that it was most accurate for a test frequency falling midway between two nearest neighbor probe calibration frequencies. The estimated uncertainty became overly pessimistic as the test frequency of interest moved closer to one of the neighboring calibrated frequencies. The procedure is improved in the present paper by the inclusion of a new term that is a function of the test frequency and the two nearest neighbor probe calibration frequencies. Examples are shown of the use of the new procedure to obtain an improved estimate of this measurement uncertainty and to create the 19th term for use with the standard 18 Term Error Table.

The RCC/SMSG Certification of Lockheed Martin Orlando Florida
L.L. Mandeville (Raytheon Electronic Systems Missile Systems),F. Plonski (NAVSEA Philadelphia ), T. Cleary (Naval Air Warfare Center Aircraft Division), November 2002

The Range Commanders Council Signature Measurement Standards Group (RCC/SMSG) Performed a Demonstration program with three DOD Radar Cross Section Ranges to evaluate and improve their documentation and evaluation process and criteria documented in what is known as a "Range Book". After a successful Demonstration Program, The RCC/SMSG has embarked on the evaluation of Industry RCS Range Calibration and measurement processes and procedures and compliance with the RCC/SMSG ANSI-Z540 (ISO-25) evaluation criteria. The Lockheed Martin Helendale RCS Range was evaluated by a committee of industry volunteers appointed by the RCC/SMSG after a review of their experience and credentials. The Lockheed Martin Orlando RCS Range requested an evaluation of their "Range Book" shortly after the completion of the Helendale evaluation. Each review committee is made up of three RCC/SMSG approved reviewers, at least one of which has participated in a previous review either as a review requester or a review committee member. This paper will put forth the process used by this review committee and the lessons learned from this and previous reviews. This paper will also discuss the RCC/SMSG process for obtaining an RCC/SMSG review.

The New Anechoic Test Range at NPL
P.R. Miller (National Physical Laboratory),A. Beardmore (National Physical Laboratory), D.G. Gentle (National Physical Laboratory), Edward Johnson (National Physical Laboratory), P.D. Lovelock (National Physical Laboratory), November 2002

NPL has recently commissioned a new indoor test range. This test range has been designed to offer Extrapolation Gain Measurements, Far-Field Probe Calibrations, and eventually, a Spherical Near-Field Test Capability. This paper describes this new range and the results of the initial validation measurements. It also compares the gains of a standard gain horn calibrated in NPL’s old Extrapolation Range with those from the new one.

A New Broadband RF Field Standard Using a Coaxial Transmission Line of Conical Geometry: Progress Report
C.M. Weil (NIST),A. Ondrejka (NIST), D.R. Novotny (NIST), R.T. Johnk (NIST), November 2001

We discuss progress in developing a new broadband (10 MHz to 40 GHz) RF field standard to be used for calibrating small electromagnetic field probes. The technique generates a well-defined and uniform TEM mode field between the conductors of an air-filled coaxial transmission line of conical geometry (termed a “co-conical” line) that is terminated in a well-matched, high-power, distributed load. We show that generation of higher-order mode fields will be minimal due to the line’s circular and symmetrical crosssection. Internal field levels equivalent to power density levels in excess of 10 mW/cm2 can be generated using broadband power sources of only 20 watts output. The new system will be capable of rapid, automated and accurate calibration of small field probes and can realize significant savings in both equipment/facility expenses and operational costs.

ANSI Z-540/ISO25 Certification Activities at the Lockheed Helendale Outdoor RCS Range
R.D. Nichols (Lockheed Martin Aeronautics),J.M. Stinson (Lockheed Martin Aeronautics), J.R. Newhouse (Lockheed Martin Aeronautics), N.E. Dougherty (Lockheed Martin Aeronautics), November 2001

In June 2001, the DoD Range Commanders Council Signature Measurement and Standards Group (RCC/SMSG) certified that the Helendale Measurement Facility (HMF) outdoor radar cross section (RCS) measurement Range Book met the ANSI-Z-540 documentation standards established by the DoD demonstration project. This paper describes how Lockheed Martin Aeronautics (LM Aero) applied the ANSI Z-540 [1,2,3] standard to obtain National Certification of the HMF RCS range. The dual calibration results for Pit #1 and Pit #3 are presented showing upper and lower uncertainty error bounds established by this process. Schedule, cost, range book format, and “lessons learned” from the LM Aero experience are also discussed.

Helendale Measurement Facility Uncertainty Analysis
J.R. Newhouse (Lockheed Martin Aeronautics),J.M. Stinson (Lockheed Martin Aeronautics), N.E. Dougherty (Lockheed Martin Aeronautics), R.D. Nichols (Lockheed Martin Aeronautics), T.J. Fischer (Lockheed Martin Aeronautics), November 2001

This paper reviews the Helendale Measurement Facility (HMF) ground plane range uncertainty analysis and associated data collection. Range uncertainty analysis is a requirement for ISO-25/ANSI-Z-540 range certification and is a priority one section in the Helendale Range Book. Targets used for the analysis were two sets of right circular “squat” calibration cylinders. These cylinders are the dual calibration cylinders for HMF. Calibration measurement uncertainties are established statistically from a large number of repeated measurements at S, C, X, and Ku bands. Each measurement was taken at two target support locations down range. The field data collected included monostatic scattering from two calibration cylinders, backgrounds with no target and support, and drift data for quality control. I and Q imbalance, frequency stability, range accuracy, linearity, and field uniformity at target locations were considered in the analysis. The uncertainty analysis is based on RSS addition of errors and assumes all errors are additive and that targets are not LO. The statistical approach used to perform the uncertainty analysis reported in this paper was developed cooperatively at AFRL and Mission Research Corporation.







help@amta.org
2025 Antenna Measurement Techniques Association. All Rights Reserved.
AMTA115x115Logo.png
 
 

CONNECT WITH US


Calendar

S M T W T F S
1 2 3
4 5 6 7 8 9 10
11 12 13 14 15 16 17
18 19 20 21 22 23 24
25 26 27 28 29 30 31